Electrical System

G500 Systems

True confession time: I am an electronics geek. I've built a television, a stereo, two computers, and all manner of test equipment. I dive into schematics as if they were mystery novels. I like this stuff. But right around the GV I started to get bored with it. The electrical system on the GV was "set and forget." The G500 seems to carry that tradition forward. On a normal ops flight you don't really do much with the electrical system. It is just there.

WORK IN PROGRESS . . . There are a lot of blank holes here. I originally built this page off the FSI Maintenance Training Manual but FlightSafety asked me to removed all their stuff. So I'll eventually rebuild this page.


images

Photo: The RAT

Click photo for a larger image

[PAS, p. 4-1] The electrical system is highly automated and requires very little crew input under normal conditions. AC power is used to create DC power which powers the majority of the aircraft’s subsystems. AC Power is normally supplied by an Integrated Drive Generator (IDG) located on each engine; however, AC Power can also be supplied by the APU Generator, Ram Air Turbine (RAT) Generator, or an External AC Power Cart for ground operations. DC Power is normally supplied by five (5) Transformer Rectifier Units (TRUs) which convert AC power to DC power. In addition to TRUs, DC Power is also available from aircraft batteries [Main Ship Batteries (2), Electrical Backup Hydraulic Actuator (EBHA) Battery, Uninterruptable Power Supply (UPS) Battery, and (2) Emergency Batteries (E-Batts)]. During ground operations, DC Power can be provided by an External DC Power Cart. AC and DC Electrical power distribution is controlled by two (2) Bus Power Control Units (BPCUs) and the Secondary Power Distribution System (SPDS). The SPDS distributes power to multiple aircraft systems. Protection is provided by traditional electro-mechanical circuit breakers and Solid State Power Controllers (SSPCs). SSPCs are part of the SPDS. SSPCs perform control (On and Off) and protection functions.

How it Works . . .

Electrical Power Generation System (EPGS)

Primary Power Distribution System (PPDS)

Secondary Power Distribution System (SPDS)

Emergency Power System

The Components in Greater Detail . . .

60 Hz Converters

AC/DC Reset / Protection Latch

APU Generator

Battery Chargers

Bus Power Control Units (BPCUs)

Cockpit Controls

Electrical Backup Hydraulic Actuator (EBHA) Battery

Electrical System Controllers (ESCs)

Emergency Batteries

External AC Source

External DC Source

Generator Control Units (GCUs)

Ground Service Bus (GSB)

Hall Effect Sensors

Integrated Drive Generators (IDGs)

Main Batteries

Modular Power Tiles (MBTs)

No Break Power Transfer (NBPT) Function

Power Distribution Boxes (PDBs)

RAM Air Turbine (RAT) Generator

Secondary Power Distribution System (SPDS)

Solid State Power Controllers (SSPC)

Transformer Rectifier Units (TRUs)

Uninterruptable Power Supply (UPS) Battery

Limitations and Abnormal Procedures . . .

Limitations

Emergency / Abnormal Operations


How it Works . . .


Electrical Power Generation System (EPGS)

Work in Progress

Primary Power Distribution System (PPDS)

Work in Progress

Secondary Power Distribution System (SPDS)

images

Photo: G500 Electrical SPDS, PAS, p. 4-19

Click photo for a larger image

[PAS, p. 4-19]

  • Distributes 115 VAC and 28 VDC to multiple aircraft systems
  • Controls “Hosted” portion of automated aircraft functions
  • Components include:
    • Electrical System Controllers (ESCs) (2). Perform system control functions (On and Off), controls some of auto functions of aircraft systems (like turning on IRUs when APU Gen comes online), send status messages to other aircraft systems via DCN, manage load shedding under abnormal conditions.
    • Modular Power Tiles (MBTs) (14): 400 Hz AC (3), 60 Hz AC (1), DC (10).
    • Solid State Power Controllers (SSPCs) located within MPTs acts as virtual circuit breakers. Will “Latch Open” for an electrical fault, eliminates weight of traditional circuit breakers, turns systems on and off when commanded by ESC.
  • Crew Interacts with SPDS via TSC #2, #3, #4, #5. Only 2 of 4 TSCs can access SPDS Menu at any given time. TSC #5 must be used to access SPDS when only ground service bus available.
  • SPDS Maintenance Test Switch located on System Monitor Test Panel is used to program SPDS into Standby or Maintenance Mode, grouping or collaring SSPCs, data loading. (Procedures found in Aircraft Maintenance Manual.)

Emergency Power System

Work in Progress


The Components in Greater Detail . . .


60 Hz Converters

images

Photo: G500 Electrical Normal Flow 60 Hz, PAS, p. 4-4

Click photo for a larger image

[PAS, p. 4-4] Two 60 Hz converters

  • Converts 115 VAC, 400 Hz, 3 Phase to 115 VAC, 60 Hz, Single Phase (Common Household Power). There are two, one in the Left Main AC and the other in the Right Main AC.
  • Located in tail compartment
  • Only one converter provides power at any given time, the other operates in standby and takes over automatically if active converter fails. The active converter switches on power up to exercise each.
  • Safety aspects: Outlet power inhibited unless a load is plugged in. Converter load sheds if cabin altitude ≥ 14,500’ to inhibit sparks with pax O2 masks deployed.
  • 60 Hz master switch is located on overhead panel, wired in series with cabin/galley master switch. When both switches are on/dark the 60 Hz converter receives power and TSC soft switches now available to allow control of each individual converter and cabin equipment.
  • Capabilities: Converters are limited to 30 Amps each. High draw items may limit ability to use every outlet at once. Cabin outlets rated 3 Amps. Galley, lavatory, baggage compartment outlets rated 15 Amps.

60Hz Ground Power Receptacle

[PAS, p. 4-6] Located in tail compartment. For cabin equipment only.

AC/DC Reset / Protection Latch

Work in Progress

APU Generator

images

Photo: G500 Electrical APU Connected, PAS, p. 4-29

Click photo for a larger image

[PAS, p. 4-2] AC power is produced by:

  • The APU generator is the primary source on the ground when engines are not operating. The APU has the same oil cooled generator as engines with same specs and powers all buses.

[PAS, p. 4-7] APU generator in flight:

  • In the event of an IDG or engine failure.
  • Capable of 100% load up to FL350.
  • Capable of 78.5% load above FL350 to FL450.

Battery Chargers

Work in Progress

EBHA Chargers

Work in Progress

Bus Power Control Units (BPCUs)

[PAS, p. 4-17] BPCUs:

  • Identical and interchangeable microprocessors.
  • Left BPCU (located in LEER PDB).
  • Right BPCU (located in REER PDB).
  • Make all logical decisions for electrical distribution and protection.
  • Output critical findings to the CAS.
  • Close and open contactors and/or relays to efficiently supply power to buses, protect and isolate the electrical system when a fault is detected.
  • Provides protection, power and logic to AC/DC reset switch.
  • Monitors External AC and DC Power. Minimum main batteries ON to monitor. If quality power illuminates “AVAIL” light on the overhead EPCP. If not quality power, trips external power contactor to protect system. Gives External AC priority to connect over external DC. If External DC is powering aircraft when AC connected, cycle external power switch OFF then ON.
  • Controls the No Break Power Transfer (NBPT) function

Cockpit Controls

images

Photo: G500 Electrical Cockpit Controls, PAS, p. 4-24

Click photo for a larger image

images

Photo: G500 Electrical Power Control Panel, PAS, p. 4-25

Click photo for a larger image

[PAS, pp. 4-26 to 4-37]

  • Left Generator Switchlight
    • IN (Normal Position). If the left engine is operating and the switchlight is pressed IN (normal position), the Left IDG will power the Left Main AC Bus, which in turn powers the Emergency AC Bus, and the L GEN “ON” legend will be illuminated.
    • IN (IDG Unpowered). When the switchlight is pressed IN and IDG is not powered by the engine, the OFF legend will illuminate and the ON legend will extinguish.
    • OUT. When the switchlight is pushed OUT, Left IDG power is isolated from the Left Main AC Bus. The OFF legend will also be illuminated in this configuration.
  • Right Generator Switchlight
    • IN (Normal Position). If the right engine is operating and the switchlight is pressed IN (normal position), the right IDG will power the right Main AC Bus and the “ON” legend will be illuminated.
    • IN (IDG Unpowered). When the switchlight is pressed IN and IDG is not powered by the engine, the OFF legend will illuminate and the ON legend will extinguish.
    • OUT. When the switchlight is pushed OUT, Right IDG power is isolated from the Right Main AC Bus. The OFF legend will also be illuminated in this configuration.
  • APU Generator Switchlight
    • When the switchlight is pressed IN (normal position), ON legend will illuminate (if the APU is running) and the APU generator will power the Left and Right Main AC Buses. If one engine is running (left engine, for example), the IDG will power the Left Main AC Bus and the APU generator will power the Right Main AC Bus. The opposite is true if the right engine only is running. If both engines are running, the IDG’s will power their respective Main AC Bus.
    • IN (APU Not Running). When the switchlight is pressed IN and APU is not running, the ON legend is extinguished. This is the normal in-flight condition because the APU is nearly always shut down in flight. The AC synoptic page will indicate an amber box surrounding the APU Generator in this condition
    • OUT. When the switchlight is pressed OUT, APU generator power will be unavailable to the Left and Right Main AC Buses and the ON legend will extinguish.
  • Ram Air Turbine Generator Guarded Switchlight
    • IN (Normal Position). When the plastic guarded switchlight is pressed IN (normal position), the amber OFF legend will extinguish and the RAT generator will power the Emergency AC Bus and the Left and Right Essential TRUs, provided the RAT is deployed
    • OUT. When the switchlight is pushed OUT, RAT generator power will be removed from the ability to power the Emergency AC Bus and the Left and Right Essential TRU’s. The amber OFF legend will also illuminate. This might be used in the event of a fault in the RAT system or if normal generator power is restored. It can also be used in the event the aircraft slows below minimum RAT operating speed of 200 knots to prevent power from possibly cycling on and off. In this case, once above 200 knots, the generator can be selected ON again (switchlight pressed IN).
  • External Power Switchlight
    • Valid AC or DC External Power Connected. Blue AVAIL legend will illuminate when AC or DC external power is plugged into the aircraft and the BPCU senses the power’s parameters are all correct for application into the aircraft. The AVAIL legend requires 24 VDC power to illuminate, so the Main Batteries would have to be selected ON. If both AC and DC external power are plugged into the aircraft, the right BPCU will prioritize the selection of AC external power.
    • IN (ON Illuminated). If the AVAIL legend is illuminated and the switchlight is pressed IN, the plugged in power source will be applied to the aircraft, the ON legend will illuminate and the AVAIL legend will extinguish.
    • IN (Both AC and DC External Power Connected). If both AC and DC external power are plugged into the aircraft and the switchlight in pushed IN, AC external power will be connected to the aircraft and the ON legend will illuminate. In this case, the AVAIL legend will stay illuminated to indicate that DC external power is plugged in and available for use.
  • AC/DC Reset Switchlight
    • Default State. Momentary contact switchlight that is normally not illuminated.
    • Fault Sensed on AC Bus. AC legend illuminating indicates the BPCU’s having sensed a fault on an AC bus. When the BPCU’s sense a fault, they will automatically isolate the AC bus from the rest of the system and lock that bus out. Even when the fault is no longer sensed, the lockout will still keep the bus isolated. An illuminated legend could also indicate a logic fault within the BPCU, or a relay or component failure. One or both of the CAS messages shown at right will appear. If the BPCU’s no longer sense the fault and the RESET switchlight is pressed, the previously tripped relays will be allowed to close and the AC legend and CAS message(s) will extinguish.
    • Fault Sensed on DC Bus. DC legend illuminating indicates the BPCU’s having sensed a fault on the DC bus. When the BPCUs sense a fault, they will automatically isolate the DC bus from the rest of the system and lock that bus out. Even when the fault is no longer sensed, the lockout will still keep the bus isolated. An illuminated legend could also indicate a logic fault within the BPCU, or a relay or component failure. One or both of the CAS messages shown at right will appear. If the BPCU’s no longer sense the fault and the RESET switchlight is pressed, the previously tripped relays will be allowed to close and the DC legend and CAS message(s) will extinguish.
    • Fault Sensed on Both AC and DC Buses. AC and DC legends illuminating indicates the BPCUs having sensed a fault on both AC and DC buses. When the BPCUs sense the fault, they will automatically isolate the faulted buses from the rest of the system and lock the buses out. Even when the fault is no longer sensed, the lockout will still keep the buses isolated. An illuminated legend could also indicate a logic fault within the BPCU, or a relay or component failure. Two or more of the CAS messages shown at right will appear. If the BPCUs no longer sense the fault and the RESET switchlight is pressed, the previously tripped relays will be allowed to close and the AC and DC legends and CAS messages will extinguish.
  • Left Bus Tie Switchlight
    • OUT (Normal Position). When the switchlight is pushed OUT (normal position), the AUTO legend will illuminate and allow BPCU logic to open and close the Bus Tie Relays as necessary to ensure buses remain powered in the event of an IDG failure.
    • IN. When the switchlight is pressed IN, ISLN L AC Isolation legend illuminates, BPCU logic is bypassed, and the Left Main AC Bus is isolated from the Right Main AC Bus.
  • Right Bus Tie Switchlight
    • OUT (Normal Position). When the switchlight is pushed OUT (normal position), the AUTO legend will illuminate and allow BPCU logic to open and close the Bus Tie Relays as necessary to ensure buses remain powered in the event of an IDG failure.
    • IN. When the switchlight is pressed IN, ISLN R AC Isolation legend illuminates, BPCU logic is bypassed, and the Right Main AC Bus is isolated from the Left Main AC Bus.

Electrical Backup Hydraulic Actuator (EBHA) Battery

images

Photo: G500 Electrical EBHA, PAS, p. 4-12

Click photo for a larger image

[PAS, p. 4-12] Electrical Backup Hydraulic Actuator (EBHA) Battery

  • 25 Volts, 53 amp/hr, Ni-Cad
  • Located in tail compartment
  • Backup power source for EBHA DC bus when emergency AC bus is unpowered. Powers Motor Control Electronics (MCEs), providing backup hydraulic and electrical power to Primary flight control surfaces and outboard spoiler panels. Lasts approximately 30 Minutes.
  • When emergency AC Bus is powered, it keeps EBHA battery charged. AC power converted to DC power via an external EBHA battery charger / TR located in tail compartment. It is powered EBHA DC Bus to maintain state of charge of EBHA battery (regardless of EBHA battery switch position).
images

Photo: G500 Electrical Aft PDB, EBHA PDB, PAS, p. 4-16

Click photo for a larger image

[PAS, p. 4-16] The EBHA PDB is in the tail compartment and contains the EBHA Bus.

[PAS, p. 4-16] EBHA Switchlights

  • IN (Normal Position). When AC power is being produced and the plastic guarded switchlight is pressed IN (normal position), the amber OFF and ON legends are extinguished and the EBHA contactor is closed, allowing power to the EBHA Bus.
  • IN (No AC Power). If the switchlight is pressed IN, the ON legend will illuminate, informing the crew that the EBHA Bus is being powered by the EBHA battery. Additionally, a light in the upper right corner of the Security/Ground Service Panel would also illuminate for this condition. The EBHA ON legend will also illuminate, informing the crew that the EBHA Bus is being powered by the EBHA battery if switch is left pressed IN and the ships batteries are selected OFF with all other power OFF
  • OUT. When the switchlight is pushed OUT, the amber OFF legend will illuminate and power is removed from the EBHA Bus.

EBHA Operation

Work in Progress

Electrical System Controllers (ESCs)

Work in Progress

Emergency Battery Packs (EBPs)

There are six major batteries of which three are nicads (2 main ship batteries and 1 for the EBHA) and three lead acids (2 EBPs and 1 UPS).

We are told that we need to open the Main Entrance Door using the emergency door panel switch to test the Fwd EBP. But the "Arm" switch has FWD and AFT capsules so doesn't it do this? Then we are told that opening the MED requires a greater amperage since a high-draw solenoid is needed to lift the door before it is allowed to fall and this is what this test is for. I'm not so sure, but this is what we are told.

images

Photo: G500 Electrical Emergency Batteries, PAS, p. 4-10

Click photo for a larger image

[PAS, p. 4-10]

  • 24 Volts, 10.5 amp/hr, lead acid with internal charger
  • Forward E-Batt located in LEER
  • Aft E-Batt located in FWD BEER
  • 3 modes of operation
    • Charge (1.5 Hours to Fully Charge), L Main AC Bus → Fwd E-Batt, R Main AC Bus → Aft E-Batt.
    • TR Mode: 24 Volts, 14 amp/hr for emergency power when power to an Ess DC Bus lost and E-Batt still receiving AC power.
    • Discharge (last resort DC power and TR mode unavailable). Provides approx 45 Mins of power for: Emergency lighting, Standby Flight Displays (SFDs), IRUs, VHF 1 Radio, Touch Screen Controllers (TSCs #2 and #3), Opening main entrance door (FWD E-Batt Only).
  • Armed E-Batts activate when L or R Ess DC Bus < 20 Volts, anytime a break power transfer occurs.
  • CAS Messages when activated: Fwd Emer Battery On, and Aft Emer Battery On.
images

Photo: G500 Electrical Emergency Power Selected Off, PAS, p. 4-38

Click photo for a larger image

[PAS, p. 4-38] Emergency Power Selected Off. If ESS DC Bus > 20V DC. Emergency Power System is Shut OFF. FWD and AFT Switch Legends Light Up Amber, indicates FWD and AFT Emer Power NOT ARMED and FWD and AFT Emer Power is OFF

images

Photo: G500 Electrical Emergency Power Selected Armed, PAS, p. 4-38

Click photo for a larger image

[PAS, p. 4-38] Emergency Power Selected ARMED. If ESS DC Bus > 20V, arms FWD and AFT E-Batts, allows Auto Switching to Emer Power When ESS DC < 20V. FWD and AFT Switch Legends Extinguish, indicates FWD and AFT Emer Power ARMED, FWD and AFT Emer Power NOT OFF.

images

Photo: G500 Electrical Emergency Power Selected On, PAS, p. 4-39

Click photo for a larger image

[PAS, p. 4-39] Emergency Power Selected ON. Can be activated 2 Ways: ON Switch Depressed or ARMED Switch Depressed and L or R ESS DC < 20V (Even Momentarily). When Activated, FWD and AFT Switch Legends Light Up Amber in ON Switch (indicates FWD and AFT E-Batts Powering L and R Emer DC Buses and Emer Lighting). CAS Messages: Aft Emer Battery On and Fwd Emer Battery On.

images

Photo: G500 Electrical Cockpit Display with Emergency Power Only, PAS, p. 4-39

Click photo for a larger image

[PAS, p. 4-39] Emergency Power Indications (Airplane Power-Up). Verify Following are Powered: Emergency Lighting, Standby Flight Displays (2), TSC #2 and #3, (Backup Engine/Radio Display, but Engine Data will be Blank)

External AC Source

images

Photo: G500 Electrical External AC Connected, PAS, p. 4-32

Click photo for a larger image

[PAS, p. 4-2] AC power is produced by:

  • External AC power cart — 30 kVA, 115 VAC, 400 Hz, 3 Phase, powers all buses.

External DC Source

images

Photo: G500 Electrical External DC Connected, PAS, p. 4-33

Click photo for a larger image

[PAS, p. 4-8] The external DC power cart powers: Left Essential DC Bus, Right Essential DC Bus, Left Main DC Bus, Right Main DC Bus (which powers the Ground Service Bus), and the Aux DC Bus.

Generator Control Units (GCUs)

The purpose of GCUs is to provide quality power by protecting and monitoring their associated generators.

[PAS, p. 4-17]

  • Produce quality power by controlling generator’s output and fault protection. When voltage, frequency or amperage out of parameter, opens contactor to take gen offline and transmits data to BPCU (except RAT GCU).
  • Engine and APU GCUs are identical and interchangeable, operate independently of each other, and are located in the LEER and REER.
  • RAT GCU is not identical to engine and APU, but similar in function.
  • GCUs reset by cycling applicable gen switch OFF then ON, re-initializes software. If failure condition still detected, GCU will again fail-safe

Ground Service Bus (GSB)

Ground Service Bus

images

Photo: G500 Electrical Various DC Panels, PAS, p. 4-6

Click photo for a larger image

[PAS, p. 4-6] Ground Service Bus (GSB)

  • Normal Power Source is Right Main DC Bus
  • Provides DC power to perform minimal aircraft ground servicing: Lights, External Water Level Indicator, Engine Oiler, Hydraulic Replenisher,Left and Right Fueling Shutoff Valves, Left and Right Fuel Quantities, Cabin Gnd Svc, Water System, TSC 5, TPMS.

[PAS, p. 4-6] On ground with Right Main DC initially unpowered

  • GSB Power Activated by Any of 4 GSB Switches Located: Tail Compartment Ground Service Panel, Security/Ground Service Panel (Left Fwd Fuselage), Refuel Panel (Right Fuselage), System Monitor Test Panel (Cockpit Fwd of REER).
  • For push button switches → Press and hold min 3 secs to activate.
  • Beacon will illuminate with a GSB switch ON.
  • Powered By: External DC if connected, Right Main Battery (if External DC not connected).
  • 1 of 4 doors must be open to power GSB from Rt Batt or Ext DC: Main Door, Tail Compartment Door, Security/Ground Service Panel Door, Refuel Panel Door

Hall Effect Sensors

What is a Hall Effect Sensor and why should you care? It is (very) basically a tiny electromagnet strapped next to a wire or other current source that detects the presence of current. So that's it: it is just a reliable way to detect current. Why should you care? I'm not sure.

For a deeper discussion about this: Hall Effect Sensors.

There are Hall Effect Sensors all over the electrical system. I'll just mention a few to give an idea about where they are and what they do. (But there are more.)

Main Ship Batteries

Work in Progress

EBHA Battery Hall Effect Sensor

Work in Progress

UPS Battery Hall Effect Sensor

Work in Progress

TRU Hall Effect Sensor

Work in Progress

Integrated Drive Generators (IDGs)

[PAS, p. 4-2] AC power is produced by:

  • Left and right engine generators (IDG’s) — Mounted on accessory gearbox of each engine, oil cooled generator produces 40 kVA, 115 VAC, 400 Hz, 3 Phase. A Constant Speed Drive (CSD) maintains constant generator speed despite variable engine speeds to produce a constant generator power output. An IDG normally powers only its respective Main AC Bus; however, any single generator (including APU), or the AC Power Cart, can provide power to both Main AC Buses via a Tie Bus.

Main Ship Batteries (MSBs)

There are six major batteries of which three are nicads (2 main ship batteries and 1 for the EBHA) and three lead acids (2 EBPs and 1 UPS).

It is said that when you are down to your MSBs, you have ten minutes left, assuming two APU start attempts.

images

Photo: G500 Electrical Main Batteries, PAS, p. 4-11

Click photo for a larger image

[PAS, p. 4-11]

  • 25 Volts, 53 amp/hr Ni-CAD (22 Volts minimum)
  • External battery chargers / TRs (2)
  • Located in tail compartment
  • 3 Modes:
    • Charge. When L / R Main AC Bus power available. Transforms 115 VAC to DC up to 32 Volts regardless of main battery switch ON or OFF, approx 90 mins to recharge battery. If battery voltage < 22V refer to Mx manual.
    • Transformer Rectifier (TR). Supplies 40 amps of DC Power when battery(s) required for APU start, aux pump operation, or when an Essential TRU fails and power needed by an Essential DC Bus. Main battery switches must be ON.
    • Discharge. When Main AC Power not available to power: APU start (Left Batt only), AUX hydraulic pump operation (L and R Batt), Left Ess DC Bus (L and R Batt), Right Ess DC Bus (L and R Batt), Ground Service Bus (Right Batt Only) when not powered by normal source of power. Will provide a minimum of 10 mins of power after 2 APU start attempts.
  • Remove for cold soak conditions (-20°C)
  • Disconnect if aircraft shutdown ≥ 5 Days

[PAS, p. 4-40] Main Battery Switches

  • OFF: switch in OUT position, legend dark.
  • ON: switch is pushed In, battery available for use according to system logic. Switch legend Amber ON for APU start, AUX pump operation, or if ESS DC buses have no other source of power.
  • OUT: switch in OUT position, legend Amber ON if an external battery switch is selected ON.
images

Photo: G500 Electrical Cockpit Display with Main Battery Power Only, PAS, p. 4-43

Click photo for a larger image

[PAS, p. 4-43] With main battery power only, you will have the following cockpit displays: OHPTS 1 and 2, Both SFDs, DUs 1 and 4, landing gear lights, and all TSCs.

Modular Power Tiles

Work in Progress

No Break Power Transfer (NBPT) Function

AC

[PAS, p. 4-18] No Break Power Transfer (NBPT) Function

  • Controlled by Left and Right BPCU
  • Prevents instability of electrically powered devices
  • Ensures AC power transfer without interruption of power. An IDG must be involved and the transfer cannot be due to a fault or failure.
  • BPCU Signals the GCU of the IDG to adjust frequency and/or phase output to match other source of AC power being applied to the electrical system. (Makes sources congruent prior to switching source.)
  • Can occur on ground or in flight

Power Distribution Boxes / Buses (PDBs)

The FSI Maintenance Manuals calls these Power Distribution Boxes while the pilot manual, Production Aircraft Systems, calls them Power Distribution Buses. The AFM? Box it is. Box or bus, a PDB is a common location where big power cables are split into smaller cables through circuit breakers.

images

Photo: G500 Electrical Left, Right PDBs, PAS, p. 4-15

Click photo for a larger image

[PAS, p. 4-15] The Power Distribution Buses (PDBs)

  • A PDB provides protection through traditional electro-magnetic circuit breakers.
  • The Left PDB is in the LEER and sends power to the Left Essential, Left Main, and Control buses.
  • The Right PDB is in the REER and sends power to the Right Essential, Right Main, External DC, Aux DC, Control, and Ground Service Bus (GSB) Control buses.

Left PDB

Work in Progress

Right PDB

Work in Progress

Aft PDB

Work in Progress

EBHA PDB

Work in Progress

RAM Air Turbine (RAT) Generator

The Ram Air Turbine provides power to your most important DC buses by powering the most important AC buses: the L ESS AC, R ESS AC, and Emer AC buses. Through that, you get power to the L ESS DC, R ESS DC, EBHA DC, and UPS DC bus.

images

Photo: G500 Electrical RAT, PAS, p. 4-7

Click photo for a larger image

[PAS, p. 4-7]

  • 15 KVA, 115 VAC, 400 Hz, 3 Phase
  • No Time Limit
  • Powers: Left Essential TRU, Right Essential TRU, Emergency AC Bus (EBHA Charger, UPS Charger, Horizontal Stab CH 1, L and R Side windshield heat).
  • Used When all generators (engine and APU) have failed or during electrical failures involving Emergency AC Bus, Left ESS DC Bus, or Right ESS DC Bus.
  • Dedicated GCU with switch located on cockpit overhead EPCP.
  • Manually Deploy: Rotate handle on floor aft of center pedestal.
  • Requirements: Deploy Mach ≤ .925, Maintain > 200 kts.
  • Can’t stow inflight; stows on ground with hand pump.

Solid State Power Controllers (SSPC)

For more about "virtual" circuit breakers, see: Circuit Breakers.

images

Photo: G500 Electrical Secondary Power Distribution System, PAS, p. 4-52

Click photo for a larger image

[PAS, p. 4-52]

  • Accessed from TSC 2 through 5
  • Distributes power to various aircraft loads (including engines)
  • Electronic System Controllers (ESC) (2) Selectable left or right (Selected is controlling, other in standby)
  • Provides summary of all SSPC’s: Tripped, Failed, Pulled, Collared
  • Search SSPC by ID / ATA #
  • Search SSPC by system
  • Navigate to cabin power page
  • Access backup system switches
images

Photo: G500 Electrical Secondary Power Distribution System, PAS, p. 4-53

Click photo for a larger image

[PAS, p. 4-53]

  • Electronic or solid state circuit breakers
  • Accessible at any time; but on GSB power → Only TSC 5 has access
  • Search by System, ID / ATA #
  • View by status: tripped, failed, pulled, collared
images

Photo: G500 Electrical Secondary Power Distribution System, PAS, p. 4-54

Click photo for a larger image

[PAS, p. 4-54] SSPCs provide detailed info for every load: Rating → Max amp, Bus → Power source, Status → Of circuit, Switch state, Current, Bus Voltage

Transformer Rectifier Units (TRUs)

images

Photo: G500 Electrical TRUs, PAS, p. 4-5

Click photo for a larger image

[PAS, p. 4-5] Five Transformer Rectifier Units (TRUs) Convert 115 VAC Power to 28 VDC Power and are dedicated to power their respective DC Bus. The Secondary Power Distribution System (SPDS) then receives DC Power from the DC Buses, except from the AUX DC Bus which routes its power to the Right PDB bypassing the SPDS.

  • The Left Main AC Bus powers the:
    • Left Ess TRU, which powers the Left Ess DC bus, which powers the SPDS and Left Emergency DC bus.
    • Left Main TRU, which powers the Left Main DC bus, which powers the SPDS.
    • Aux TRU, which powers the AUX DC Bus.
  • The Right Main AC Bus powers the:
    • Right Ess TRU, which powers the Right Ess DC Bus, which powers the SPDS and Right Emergency DC bus.
    • Right Main TRU, which power the Right Main DC bus, which powers the SPDS and Ground Service Bus.
    • AUX TRU if the Left Main AC Bus isn't powered.

[PAS, p. 4-9] If a TRU failure occurs:

  • AUX TRU sheds power to the AUX DC bus and you will lose power to non-essential cabin equipment.
  • AUX TRU then powers one of the buses connected to a failed TRU under the priority essential before main, and left before right.
  • The priority logic is carried out by the BPCUs and is repeated for additional TRU failures.

Uninterruptable Power Supply (UPS) Battery

There are six major batteries of which three are nicads (2 main ship batteries and 1 for the EBHA) and three lead acids (2 EBPs and 1 UPS).

images

Photo: G500 Electrical UPS, PAS, p. 4-13

Click photo for a larger image

[PAS, p. 4-13] Uninterruptable Power Supply (UPS) Battery

  • 24 Volts, 10.5 amp/hr, Lead Acid
  • Located in REER
  • Backup power source for UPS DC bus when emergency AC bus is unpowered. Components powered: 2 of 4 FCC Channels (1A and 2B), Backup Flight Control Unit (BFCU), 1 of 2 power sources for all REUs. Lasts Approximately 30 Minutes.
  • When emergency AC Bus is powered, it keeps UPS battery charged. AC Power converted to DC power via the UPS battery’s charger / TR.
  • Gulfstream Recommends Performing an Immediate Landing when Operating on Main, UPS and EBHA Batteries Only.

[PAS, p. 4-45] UPS Switchlights

  • IN (Normal Position). When AC power is being produced and the plastic guarded switchlight is pressed IN (normal position), the amber OFF and ON legends are extinguished and the UPS contactor is closed, allowing power to the UPS Bus.
  • IN (No AC Power). If the switchlight is pressed IN, the ON legend will illuminate, informing the crew that the UPS Bus is being powered by the UPS battery. Additionally, a light in the upper right corner of the Security/Ground Service Panel would also illuminate for this condition.
  • OUT. When the switchlight is pushed OUT, the amber OFF legend will illuminate and power is removed from the UPS Bus.

Limitations and Abnormal Procedures


Limitations

[AFM, §01-24-10]

  • Deployment of the RAT is prohibited when normal AC power is available except during emergency conditions and as directed by abnormal or emergency procedure checklists.

  • Minimum airspeed for effective RAT operation is 200 KCAS.

References

Gulfstream GVII-G500 Production Aircraft Systems, Revision 1, Oct 1, 2018