Engine Fire on Ground

G500 Emergency Procedures

This is a work in progress


AFM Procedure

[AFM, §04-10-20]

Possible Cause

Engine fire loop senses fire in Zone 1 of the engine.

images

Click photo for a larger image

Corrective Action

  1. POWER LEVERS . . . IDLE

  2. Airplane . . . Stop

  3. PARKING BRAKE . . . Set

  4. FUEL CONTROLS (Left and Right) . . . OFF

  5. Affected Engine . . . Confirm

  6. FIRE Handle (Affected Engine) . . . Pull

  7. FIRE Handle (Affected Engine) . . . DISCH 1

  8. If fire indications remain displayed after 30 seconds:

    1. FIRE Handle (Affected Engine) . . . DISCH 2

  9. Refer to 04-19-50, Emergency Airplane Evacuation.

References

Gulfstream GVII-G500 Airplane Flight Manual, Revision 1, August 31, 2018

Revision: 2019-04-30
Top